The combo system designed for flexibility in pediatric cardiology.

One Platform. Designed for Two Pediatric Applications.
The evolution duo natal combines pediatric hemodynamics with electrophysiology in one integrated platform, providing the flexibility to perform both clinical applications within a single system.
Designed for smart integration, the optional zero-footprint setup positions the system hardware outside the procedure room, creating valuable workspace while providing full functionality for both hemodynamic and electrophysiological procedures.
Precise hemodynamic measurements and EP signal recording, combined with dedicated software solutions and Smart Keyboard for each application, support intuitive operation tailored to pediatric procedures.
Designed for reliable performance across both applications, evolution duo natal brings specialized hemodynamics and electrophysiology together in one flexible solution.
Smart. Precise. Reliable.
Tailored for Pediatric Cardiology
Flexible measurement capabilities and specialized tools designed to meet the unique requirements of pediatric cardiac catheterization.
- Invasive blood pressures
- 12- lead ECG
- Non-invasive blood pressure
- SpO2
- Cardiac output (Thermodilution and Fick)
- Temperature
- Respiratory rate
- Calculation and visualization of shunts, stenosis, valve areas
- FFR (integrable or third-party solutions)
- Freely configurable measurement points
- Tailored measurements and calculations for pediatric cardiology
- Optional PedCath connectivity
- Adaptable to complex anatomies and changing clinical requirements
Designed for Electrophysiology
The EP-TRACER® 2 features a fully integrated stimulator designed to simplify stimulation and support an efficient procedural workflow.
- Sharply defined intracardiac signals (either 20, 52 or 84 bipolar intracardiac channels)
- Connectivity to PFA, Cryo and RF generator
- Intuitive software interface for easy and efficient operation
- One-Touch control of key functions via the Smart Keyboard
- Three different viewing modes
- Invasive blood pressure display
- Export of calibrated signals (in mV)
- Review possibility
- CSP Upgrade
Integrated Data Management
Centralize patient data, waveforms and reports in one intuitive system for seamless documentation and long-term data accessibility.
- Full disclosure files
- Capture and store waveforms
- Report (stored data, analysis, and waves)
- Interfaces to Information Systems (DICOM interface)
Integrated Stimulator
The EP-TRACER® 2 features a fully integrated stimulator designed to simplify stimulation and support an efficient procedural workflow.
- Built-in 2-channel stimulator
- Stimulate on any intracardiac channel with a single click
- No external wiring or additional equipment required
- Easily customizable stimulation protocols
- Designed to streamline the procedural workflow
IT components
- 2 × 24“ TFT monitors
- disinfectable keyboard
- disinfectable mouse
- 19“ PC (64bit, Windows 10 IoT)
Options
- Vital signs for Cardiac Output, NiBP, SpO2
Cabeling
- Cable for catheter connection box (approx. 3 m)
- 12 – lead ECG cable
- X-ray translucent extension cable
Designed for simplicity from the very first use, the Smart Keyboard combines intuitive operation with a minimal learning curve to support efficient and pediatric cardiac catheterization and EP workflows.
Intuitive icons make the software’s key functions instantly understandable, allowing every user to operate the system with minimal training.
- Intuitive user interface
- One-touch operation
- Minimal learning curve
“Simplicity is the ultimate sophistication.”
Leonardo da Vinci

evolution duo
| Integrable Amplifier – Hemo/EP | Size: 240 x 125 x 52 / 265 x 200 x 65, 110 x 290 x 260 (mm) Weight: 920g / approx. 800g, 2.2 – 3.8 kg |
| Classification according to European Medical Device Directive(93/42/EEC) |
Class IIb |
| Electrical safety | Safety class I |
| Patient safety | Applied Parts Type CF (according to IEC 60601-1) |
| Surface ECGs – Hemo/EP | Sampling rate: 1000 Hz Leads: I, II, III, aVL, aVR, aVF V1-V6 QRS amplitude: 0.15 … 10mV |
| Invasive blood pressure – Hemo | Number of inputs: 4 channels Sampling rate: 500 Hz Display scales: 10, 25, 50, 100, 200, 400 mmHg |
| Analog Outputs – Hemo | 2 outputs Signal range: +/- 5 V QRS trigger: 1 – 25V; max delay 35 ms |
|
Intracardiac ECG |
Number of channels: 20/52/84 Input mode: bipolar or unipolar Sampling rate: 1000 Hz |
|
Current leakage |
< 50 μA |
|
Back-up stimulations mode |
60 beats per min at Out1-Out2 current = 8mA (Out1), current = 4mA (Out2), pulse amplitude = 2msec |
| Stimulator
|
Current 0.5 – 25.5mA (customizable) Minimum increment 0.5 mA |
| Options – Hemo | |
| Cardiac Output | Sampling rate: 250 Hz Resolution: 0.01 l/min Measurement method: Thermodilution |
| SpO2 | 0-100% measurement range Resolution: 1% |
| NiBP | SYS: 25 to 290 mmHg DIA: 15 to 250 mmHg Resolution: 1 mmHg |
| Standards | EN 60601-1:2006 + A1:2013 EN 60601-2-27:2014 EN 60601-2-34:2014 EN ISO 14971:2019 for further applied standards see accompanying papers |
More Combined Solutions Hemo-EP Products

evolution duo
The combo system designed for flexibility.
Technical Support
Take advantage of optional service contracts for maintenance, digital trainings, and fast technical support-tailored to your specific needs.
Contact us
| info@schwarzercardiotek.com | |
| Phone | +49 (0)7131 2774 500 |